نام دستورات
|
دستور
|
بایت صحت پکت پاسخ
|
فرمول
|
مقدار کمینه پارامتر
|
مقدار بیشینه پارامتر
|
واحد اندازهگیری
|
6 C drop condition fulfilled for leak test(Hev)
|
22 E0 25
|
62 E0
|
B[9]&(1<<6)
|
0
|
0
|
on/off state
|
دماي محيط از NVLD(HEV)
|
22 E0 25
|
62 E0
|
B[8]*0.75-48
|
0
|
0
|
°C
|
duration of switch closed time during leak test(Hev)
|
22 E0 25
|
62 E0
|
B[11]*10
|
0
|
0
|
min
|
NVLD switch(HEV)
|
22 E0 25
|
62 E0
|
B[9]&(1<<7)
|
0
|
0
|
on/off state
|
A/C compressor ON by ECU
|
22 E0 04
|
62 E0
|
B[11]&(1<<5)
|
0
|
0
|
on/off state
|
A/C on condition
|
22 E0 04
|
62 E0
|
B[11]&(1<<6)
|
0
|
0
|
on/off state
|
A/C pressure switch
|
22 E0 04
|
62 E0
|
B[11]&(1<<4)
|
0
|
0
|
on/off state
|
AC request to ECU
|
22 E0 04
|
62 E0
|
B[11]&(1<<7)
|
0
|
0
|
on/off state
|
brake lamp switch
|
22 E0 04
|
62 E0
|
B[9]&(1<<5)
|
0
|
0
|
on/off state
|
brake test switch
|
22 E0 04
|
62 E0
|
B[9]&(1<<4)
|
0
|
0
|
on/off state
|
canister close valve(option)
|
22 E0 04
|
62 E0
|
B[14]&(1<<5)
|
0
|
0
|
on/off state
|
catalyst heating is active
|
22 E0 04
|
62 E0
|
B[10]&(1<<5)
|
0
|
0
|
on/off state
|
clutch pedal switch(mt&acc only)
|
22 E0 04
|
62 E0
|
B[9]&(1<<6)
|
0
|
0
|
on/off state
|
cooling fan relay-high
|
22 E0 04
|
62 E0
|
B[17]&(1<<5)
|
0
|
0
|
on/off state
|
cooling fan relay-low
|
22 E0 04
|
62 E0
|
B[17]&(1<<6)
|
0
|
0
|
on/off state
|
cruise control active(option)
|
22 E0 04
|
62 E0
|
B[19]&(1<<7)
|
0
|
0
|
on/off state
|
cruise control main lamp(option)
|
22 E0 04
|
62 E0
|
B[18]&(1<<7)
|
0
|
0
|
on/off state
|
cruise control set lamp(option)
|
22 E0 04
|
62 E0
|
B[18]&(1<<6)
|
0
|
0
|
on/off state
|
CVVL controller active-exhuast(option)
|
22 E0 04
|
62 E0
|
B[23]&(1<<6)
|
0
|
0
|
on/off state
|
CVVL controller active-intake
|
22 E0 04
|
62 E0
|
B[23]&(1<<7)
|
0
|
0
|
on/off state
|
engine running detected
|
22 E0 04
|
62 E0
|
B[13]&(1<<5)
|
0
|
0
|
on/off state
|
evap purge control active
|
22 E0 04
|
62 E0
|
B[14]&(1<<7)
|
0
|
0
|
on/off state
|
fuel cut status
|
22 E0 04
|
62 E0
|
B[12]&(1<<4)
|
0
|
0
|
on/off state
|
fuel pump on
|
22 E0 04
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
on/off state
|
ignition switch
|
22 E0 04
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
on/off state
|
knock detected-S1B1
|
22 E0 04
|
62 E0
|
B[25]&(1<<7)
|
0
|
0
|
on/off state
|
knock detected-S2B2
|
22 E0 04
|
62 E0
|
B[25]&(1<<6)
|
0
|
0
|
on/off state
|
lambda closed loop active
|
22 E0 04
|
62 E0
|
B[10]&(1<<4)
|
0
|
0
|
on/off state
|
lambda fuel trim active downstream-bank1
|
22 E0 04
|
62 E0
|
B[20]&(1<<5)
|
0
|
0
|
on/off state
|
lambda fuel trim active downstream-bank2
|
22 E0 04
|
62 E0
|
B[21]&(1<<5)
|
0
|
0
|
on/off state
|
main relay on
|
22 E0 04
|
62 E0
|
B[8]&(1<<4)
|
0
|
0
|
on/off state
|
malfunction indicator lamp(MIL)
|
22 E0 04
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
on/off state
|
O2 sensor is ready for operation-bank1 downstream
|
22 E0 04
|
62 E0
|
B[20]&(1<<6)
|
0
|
0
|
on/off state
|
O2 sensor is ready for operation-bank1 upstream
|
22 E0 04
|
62 E0
|
B[20]&(1<<7)
|
0
|
0
|
on/off state
|
O2 sensor is ready for operation-bank 2 downstream
|
22 E0 04
|
62 E0
|
B[21]&(1<<6)
|
0
|
0
|
on/off state
|
O2 sensor is ready for operation-bank 2 upstream
|
22 E0 04
|
62 E0
|
B[21]&(1<<7)
|
0
|
0
|
on/off state
|
overheat protection active-bank1
|
22 E0 04
|
62 E0
|
B[20]&(1<<4)
|
0
|
0
|
on/off state
|
overheat protection active-bank2
|
22 E0 04
|
62 E0
|
B[21]&(1<<4)
|
0
|
0
|
on/off state
|
power steering switch(option)
|
22 E0 04
|
62 E0
|
B[10]&(1<<7)
|
0
|
0
|
on/off state
|
synchronization succeed(cmp/ckp)
|
22 E0 04
|
62 E0
|
B[14]&(1<<4)
|
0
|
0
|
on/off state
|
TCI bypass valve activation
|
22 E0 04
|
62 E0
|
B[15]&(1<<7)
|
0
|
0
|
on/off state
|
throttle position closed(idle)
|
22 E0 04
|
62 E0
|
B[9]&(1<<7)
|
0
|
0
|
on/off state
|
throttle position full open
|
22 E0 04
|
62 E0
|
B[13]&(1<<7)
|
0
|
0
|
on/off state
|
VIS control state
|
22 E0 04
|
62 E0
|
B[15]&(1<<4)
|
0
|
0
|
on/off state
|
A/C pressure
|
22 E0 14
|
62 E0
|
B[18]*13.79
|
0
|
0
|
kPa
|
A/C pressure voltage
|
22 E0 14
|
62 E0
|
B[17]B[16]*0.00487998779
|
0
|
0
|
v
|
cooling fan relay-PWM
|
22 E0 14
|
62 E0
|
B[15]*0.39
|
0
|
0
|
%
|
ECWP RPM
|
22 E0 14
|
62 E0
|
B[62]B[61]*1
|
0
|
0
|
rpm
|
fault flag for ECWP
|
22 E0 14
|
62 E0
|
B[63]&(1<<6)
|
0
|
0
|
brake pedal switch open
|
max adapted BOL value over all DC
|
22 E0 14
|
62 E0
|
B[70]*0.0001568627450
|
0
|
0
|
v
|
port flap cleanness check at closed position
|
22 E0 14
|
62 E0
|
B[53]&(1<<7)
|
0
|
0
|
Ok/error
|
port flap cleanness check at open position
|
22 E0 14
|
62 E0
|
B[54]&(1<<7)
|
0
|
0
|
Ok/error
|
port flap durability check at closed position
|
22 E0 14
|
62 E0
|
B[55]&(1<<7)
|
0
|
0
|
Ok/error
|
port flap durability check at closed position
|
22 E0 14
|
62 E0
|
B[60]&(1<<7)
|
0
|
0
|
Ok/error
|
position of EGRV actuator
|
22 E0 14
|
62 E0
|
B[67]B[66]>32767 ? (B[67]B[66]-65536)*0.006103740923:B[67]B[66]*0.006103740923
|
0
|
0
|
%
|
power steering pressure sensor voltage(option)
|
22 E0 14
|
62 E0
|
B[24]B[23]*0.004879987792
|
0
|
0
|
v
|
power steering pressure(option)
|
22 E0 14
|
62 E0
|
B[25]*0.1
|
0
|
0
|
Mpa
|
protection flag for ECWP
|
22 E0 14
|
62 E0
|
B[63]&(1<<7)
|
0
|
0
|
brake pedal switch open
|
PWM at VCM actuator(option)
|
22 E0 14
|
62 E0
|
B[35]B[34]>32767 ? (B[35]B[34]-65536)*0.003000091914:B[35]B[34]*0.003000091914
|
0
|
0
|
%
|
PWM of EGRV actuator
|
22 E0 14
|
62 E0
|
B[69]B[68]>32767 ? (B[69]B[68]-65536)*0.00305187046:B[69]B[68]*0.00305187046
|
0
|
0
|
%
|
VCM closed postiion-adaptation value difference
|
22 E0 14
|
62 E0
|
B[50]B[49]*0.0048827344
|
0
|
0
|
v
|
VCM closed position-first adaption value
|
22 E0 14
|
62 E0
|
B[46]B[45]*0.0048827344
|
0
|
0
|
v
|
VCM open position-adaptation value difference
|
22 E0 14
|
62 E0
|
B[52]B[51]*0.004882734416
|
0
|
0
|
v
|
VCM open position-first adaption value
|
22 E0 14
|
62 E0
|
B[48]B[47]*0.004882734416
|
0
|
0
|
v
|
VCM port flap position(option)
|
22 E0 14
|
62 E0
|
B[39]B[38]>32767 ? (B[39]B[38]-65536)*0.02439995097:B[39]B[38]*0.02439995097
|
0
|
0
|
degree port
|
VCM port flap setpoint(option)
|
22 E0 14
|
62 E0
|
B[40]*1
|
0
|
0
|
degree port
|
VCM-first adaptation values valid
|
22 E0 14
|
62 E0
|
B[44]*1
|
0
|
0
|
|
voltage input from VCM feedback sensor(option)
|
22 E0 14
|
62 E0
|
B[37]B[36]*0.00487998779
|
0
|
0
|
v
|
voltage of EGRV actuator
|
22 E0 14
|
62 E0
|
B[65]B[64]>32767 ? (B[65]B[64]-65536)*0.000152578203989:B[65]B[64]*0.000152578203989
|
0
|
0
|
v
|
موقعيت پدال گاز
|
22 E0 1F
|
62 E0
|
B[28]*0.3906274509803
|
0
|
0
|
%
|
acceleration pedal position sensor-1 voltage
|
22 E0 1F
|
62 E0
|
B[30]B[29]*0.0048828870069
|
0
|
0
|
v
|
acceleration pedal position sensor-2 voltage
|
22 E0 1F
|
62 E0
|
B[32]B[31]*0.0048828870069
|
0
|
0
|
v
|
cruise signal acquistion configuration
|
22 E0 1F
|
62 E0
|
B[55]%4
|
0
|
0
|
cruise signal acquistion configuration
|
cruise switch status(option)
|
22 E0 1F
|
62 E0
|
B[45]
|
0
|
0
|
وضعيت سوييچ کروز-گزينه
|
ETC motor duty
|
22 E0 1F
|
62 E0
|
B[34]B[33]>32767 ? (B[34]B[33]-65536)*0.00305003217:B[34]B[33]*0.00305003217
|
0
|
0
|
%
|
sensor reference voltage1(TPS)
|
22 E0 1F
|
62 E0
|
B[36]B[35]*0.009799954222
|
0
|
0
|
v
|
sensor reference voltage-2
|
22 E0 1F
|
62 E0
|
B[38]B[37]*0.009799954222
|
0
|
0
|
v
|
sensor reference voltage-3
|
22 E0 1F
|
62 E0
|
B[40]B[39]*0.009799954222
|
0
|
0
|
v
|
sensor reference voltage-4
|
22 E0 1F
|
62 E0
|
B[42]B[41]*0.009799954222
|
0
|
0
|
v
|
throttle position sensor angle 1
|
22 E0 1F
|
62 E0
|
B[9]B[8]*0.00732417792
|
0
|
0
|
degree TPS
|
throttle position sensor angle 2
|
22 E0 1F
|
62 E0
|
B[11]B[10]*0.00732417792
|
0
|
0
|
degree TPS
|
throttle position sensor angle 1-voltage
|
22 E0 1F
|
62 E0
|
B[15]B[14]*0.004882887006
|
0
|
0
|
v
|
throttle position sensor angle 2-voltage
|
22 E0 1F
|
62 E0
|
B[17]B[16]*0.004882887006
|
0
|
0
|
v
|
TPS set point
|
22 E0 1F
|
62 E0
|
B[13]B[12]*0.00732417792
|
0
|
0
|
TPS
|
actual engine speed
|
22 E0 01
|
62 E0
|
B[12]B[11]*0.25
|
0
|
0
|
rpm
|
دماي محيط
|
22 E0 01
|
62 E0
|
B[32]*0.75-48
|
0
|
0
|
°C
|
barometric pressure sensor voltage
|
22 E0 01
|
62 E0
|
B[34]B[33]*0.004882887006
|
0
|
0
|
v
|
ولتاژ باتري
|
22 E0 01
|
62 E0
|
B[8]*0.068117647058
|
0
|
0
|
v
|
battery voltage after IG key
|
22 E0 01
|
62 E0
|
B[9]*0.068117647058
|
0
|
0
|
v
|
دماي روغن موتور
|
22 E0 01
|
62 E0
|
B[38]*0.75-48
|
0
|
0
|
°C
|
fuel level(option)
|
22 E0 01
|
62 E0
|
B[39]*1
|
0
|
0
|
%
|
fuel tank pressure value(option)
|
22 E0 01
|
62 E0
|
B[41]B[40]>32767 ? (B[41]B[40]-65536)*0.00122001286:B[41]B[40]*0.00122001286
|
0
|
0
|
hpa
|
intake air temperature
|
22 E0 01
|
62 E0
|
B[37]*0.75-48
|
0
|
0
|
°C
|
intake air temperature voltage
|
22 E0 01
|
62 E0
|
B[36]B[35]*0.004882887006
|
0
|
0
|
v
|
intake manifold pressure
|
22 E0 01
|
62 E0
|
B[21]B[20]*0.03906248569
|
0
|
0
|
hpa
|
mass air flow sensor value
|
22 E0 01
|
62 E0
|
B[17]B[16]*0.1
|
0
|
0
|
kg/h
|
pressure sensor(MAP)signal voltage
|
22 E0 01
|
62 E0
|
B[19]B[18]*0.004882887006
|
0
|
0
|
v
|
target idle RPM
|
22 E0 01
|
62 E0
|
B[13]*10
|
0
|
0
|
rpm
|
water temperature
|
22 E0 01
|
62 E0
|
B[29]*0.75-48
|
0
|
0
|
°C
|
water temperature voltage
|
22 E0 01
|
62 E0
|
B[28]B[27]*0.004882887006
|
0
|
0
|
v
|
actual lambda value-bank1
|
22 E0 16
|
62 E0
|
B[16]B[15]*0.00024414435034
|
0
|
0
|
|
internal resistance of downstream oxygen sensor-bank1
|
22 E0 16
|
62 E0
|
B[12]B[11]*1
|
0
|
0
|
Ohm
|
internal resistance of upstream oxygen sensor-bank1
|
22 E0 16
|
62 E0
|
B[10]B[9]*1
|
0
|
0
|
Ohm
|
lambda sensor correction value-bank1
|
22 E0 16
|
62 E0
|
B[20]B[19]>32767 ? (B[20]B[19]-65536)*0.001524862894:B[20]B[19]*0.001524862894
|
0
|
0
|
%
|
off duration O2 sensor heating downstream catalyst bank1
|
22 E0 16
|
62 E0
|
B[29]*0.39098039215
|
0
|
0
|
%
|
off duration O2 sensor heating upstream catalyst bank1
|
22 E0 16
|
62 E0
|
B[28]*0.39098039215
|
0
|
0
|
%
|
required lambda-bank1
|
22 E0 16
|
62 E0
|
B[14]B[13]*0.00024414435034
|
0
|
0
|
|
actual lambda value-bank2
|
22 E0 17
|
62 E0
|
B[15]B[14]*0.0002441443503
|
0
|
0
|
|
internal resistance of downstream oxygen sensor-bank2
|
22 E0 17
|
62 E0
|
B[11]B[10]*1
|
0
|
0
|
Ohm
|
internal resistance of upstream oxygen sensor-bank2
|
22 E0 17
|
62 E0
|
B[9]B[8]*1
|
0
|
0
|
Ohm
|
lambda sensor correction value-bank2
|
22 E0 17
|
62 E0
|
B[19]B[18]>32767 ? (B[19]B[18]-65536)*0.001524862894:B[19]B[18]*0.001524862894
|
0
|
0
|
%
|
off duration O2 sensor heating downstream catalyst bank2
|
22 E0 17
|
62 E0
|
B[28]*0.39098039215
|
0
|
0
|
%
|
off duration O2 sensor heating upstream catalyst bank2
|
22 E0 17
|
62 E0
|
B[27]*0.39098039215
|
0
|
0
|
%
|
required lambda-bank 2
|
22 E0 17
|
62 E0
|
B[13]B[12]*0.00024414435034
|
0
|
0
|
|
actual position of CVVL control shaft angle(CVVL)
|
22 E0 28
|
62 E0
|
B[13]B[12]*0.012207064927
|
0
|
0
|
%
|
actual position of the valve lift(CVVL)
|
22 E0 28
|
62 E0
|
B[29]B[28]*0.00099992370489
|
0
|
0
|
mm
|
barcode written cylinder#1 valve lift value(CVVL)
|
22 E0 28
|
62 E0
|
B[45]B[44]*0.000999923704
|
0
|
0
|
mm
|
barcode written cylinder#2 valve lift value(CVVL)
|
22 E0 28
|
62 E0
|
B[47]B[46]*0.000999923704
|
0
|
0
|
mm
|
barcode written cylinder#3 valve lift value(CVVL)
|
22 E0 28
|
62 E0
|
B[49]B[48]*0.000999923704
|
0
|
0
|
mm
|
barcode written cylinder#4 valve lift value(CVVL)
|
22 E0 28
|
62 E0
|
B[51]B[50]*0.000999923704
|
0
|
0
|
mm
|
CVVL DC motor control current(CVVL)
|
22 E0 28
|
62 E0
|
B[19]B[18]>32767 ? (B[19]B[18]-65536)*0.00317993811:B[19]B[18]*0.00317993811
|
0
|
0
|
A
|
final cylinder #1 valve lift tolerance(CVVL)
|
22 E0 28
|
62 E0
|
B[37]B[36]>32767 ? (B[37]B[36]-65536)*0.00100003063:B[37]B[36]*0.00100003063
|
0
|
0
|
mm
|
final cylinder #2 valve lift tolerance(CVVL)
|
22 E0 28
|
62 E0
|
B[39]B[38]>32767 ? (B[39]B[38]-65536)*0.00100003063:B[39]B[38]*0.00100003063
|
0
|
0
|
mm
|
final cylinder #3 valve lift tolerance(CVVL)
|
22 E0 28
|
62 E0
|
B[41]B[40]>32767 ? (B[41]B[40]-65536)*0.00100003063:B[41]B[40]*0.00100003063
|
0
|
0
|
mm
|
final cylinder #4 valve lift tolerance(CVVL)
|
22 E0 28
|
62 E0
|
B[43]B[42]>32767 ? (B[43]B[42]-65536)*0.00100003063:B[43]B[42]*0.00100003063
|
0
|
0
|
mm
|
leanred bottom limit value of CVVL control shaft angle(CVVL)
|
22 E0 28
|
62 E0
|
B[9]B[8]*0.021969939726
|
0
|
0
|
|
learned top limit value of CVVL control shaft angle(CVVL)
|
22 E0 28
|
62 E0
|
B[11]B[10]*0.021969939726
|
0
|
0
|
|
memorized peak to peak difference of valve lift(CVVL)
|
22 E0 28
|
62 E0
|
B[53]B[52]*0.001001449607
|
0
|
0
|
mm
|
modeling temperature of CVVL DC motor(CVVL)
|
22 E0 28
|
62 E0
|
B[23]B[22]>32767 ? (B[23]B[22]-65536)*0.007799871319:B[23]B[22]*0.007799871319
|
0
|
0
|
°C
|
output PWM of CVVL DC motor control(CVVL)
|
22 E0 28
|
62 E0
|
B[21]B[20]>32767 ? (B[21]B[20]-65536)*0.00610404730:B[21]B[20]*0.00610404730
|
0
|
0
|
%
|
target angle position of CVVL control shaft angle(CVVL)
|
22 E0 28
|
62 E0
|
B[15]B[14]*0.012207064927
|
0
|
0
|
%
|
target position of the valve lift(CVVL)
|
22 E0 28
|
62 E0
|
B[27]B[26]*0.0009999237048905165
|
0
|
0
|
mm
|
temperature of the control circuit for CVVL DC motor control(CVVL)
|
22 E0 28
|
62 E0
|
B[25]B[24]>32767 ? (B[25]B[24]-65536)*0.00781243297:B[25]B[24]*0.00781243297
|
0
|
0
|
°C
|
written counter of CVVL code by scan tool(CVVL)
|
22 E0 28
|
62 E0
|
B[60]*1
|
0
|
0
|
|
adaptation excess flag by writing the barcode(CVVL)
|
22 E0 26
|
62 E0
|
B[9]&(1<<4)
|
0
|
0
|
on/off state
|
adaptation status at idling by scan tool(CVVL)
|
22 E0 26
|
62 E0
|
B[10]&(1<<6)
|
0
|
0
|
on/off state
|
adaptation status for compensation between the engine(CVVL)
|
22 E0 26
|
62 E0
|
B[10]&(1<<7)
|
0
|
0
|
on/off state
|
adaptation tolerance excess flag for CVVL aging(CVVL)
|
22 E0 26
|
62 E0
|
B[10]&(1<<4)
|
0
|
0
|
on/off state
|
complete status of CVVL mechanical adaptation(CVVL)
|
22 E0 26
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
on/off state
|
request signal detection for writing CVVL barcode(CVVL)
|
22 E0 26
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
on/off state
|
state of CVVL barcode adaptation(CVVL)
|
22 E0 26
|
62 E0
|
B[8]&(1<<4)
|
0
|
0
|
good 1/imbalance 0
|
status of CVVL DC motor relay(CVVL)
|
22 E0 26
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
on/off state
|
adapted ambient pressure
|
22 E0 11
|
62 E0
|
B[46]B[45]*0.08291004806
|
0
|
0
|
hpa
|
barometric pressure sensor
|
22 E0 11
|
62 E0
|
B[44]B[43]*0.082910048065
|
0
|
0
|
hpa
|
calculated oil temperature
|
22 E0 11
|
62 E0
|
B[42]*1-40
|
0
|
0
|
°C
|
engine operating status
|
22 E0 11
|
62 E0
|
B[23]
|
0
|
0
|
engine operation status
|
ignition output value-cyl1
|
22 E0 11
|
62 E0
|
B[9]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl2
|
22 E0 11
|
62 E0
|
B[10]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl3
|
22 E0 11
|
62 E0
|
B[11]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl4
|
22 E0 11
|
62 E0
|
B[12]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl5
|
22 E0 11
|
62 E0
|
B[13]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl6
|
22 E0 11
|
62 E0
|
B[14]*0.75-95.25
|
0
|
0
|
CRK
|
ignition output value-cyl7
|
22 E0 11
|
62 E0
|
B[15]*0.75-95.25
|
0
|
0
|
CRK
|
torque converter turbine speed
|
22 E0 11
|
62 E0
|
B[38]B[37]>32767 ? (B[38]B[37]-65536)*1:B[38]B[37]*1
|
0
|
0
|
rpm
|
adaption of fuel feedback by ethanol ratio
|
22 E0 29
|
62 E0
|
B[11]*0.781254901960
|
0
|
0
|
%
|
content of ethanol in fuel tank
|
22 E0 29
|
62 E0
|
B[8]*0.7812549019607
|
0
|
0
|
%
|
factor for adaption of the ethanol fuel ration
|
22 E0 29
|
62 E0
|
B[10]B[9]*6.25
|
0
|
0
|
%
|
adaption value for the lower mechanical stop of EWGA(bank1)
|
22 E0 21
|
62 E0
|
B[53]>127 ? (B[53]-256)*0.03921259842:B[53]*0.03921259842
|
0
|
0
|
v
|
EWG closed adaptation-max at IG key on(bank 1)
|
22 E0 21
|
62 E0
|
B[63]B[62]>32767 ? (B[63]B[62]-65536)*0.000152578203989:B[63]B[62]*0.000152578203989
|
0
|
0
|
v
|
EWG closed adaptation-max during eng running(bank11)
|
22 E0 21
|
62 E0
|
B[65]B[64]>32767 ? (B[65]B[64]-65536)*0.000152578203989:B[65]B[64]*0.000152578203989
|
0
|
0
|
v
|
EWG closed adaptation-min at IG key on(bank1)
|
22 E0 21
|
62 E0
|
B[67]B[66]>32767 ? (B[67]B[66]-65536)*0.000152578203989:B[67]B[66]*0.000152578203989
|
0
|
0
|
v
|
EWG closed adaptation-min during eng running(bank1)
|
22 E0 21
|
62 E0
|
B[69]B[68]>32767 ? (B[69]B[68]-65536)*0.000152578203989:B[69]B[68]*0.000152578203989
|
0
|
0
|
v
|
PWM at EPC for WG actuation
|
22 E0 21
|
62 E0
|
B[9]B[8]*0.00152574959
|
0
|
0
|
%
|
turbo charger boost pressure
|
22 E0 21
|
62 E0
|
B[13]B[12]*0.082910048065
|
0
|
0
|
hpa
|
voltage for wastegate position(ewga)(bank1)
|
22 E0 21
|
62 E0
|
B[55]B[54]>32767 ? (B[55]B[54]-65536)*0.000152578203989:B[55]B[54]*0.000152578203989
|
0
|
0
|
v
|
wastegate control PWM(EWGA)(bank1)
|
22 E0 21
|
62 E0
|
B[57]B[56]>32767 ? (B[57]B[56]-65536)*0.00305187046:B[57]B[56]*0.00305187046
|
0
|
0
|
%
|
wastegate position
|
22 E0 21
|
62 E0
|
B[49]B[48]*0.00729411764
|
0
|
0
|
TPS
|
wastegate position setpoint
|
22 E0 21
|
62 E0
|
B[51]B[50]*0.00729411764
|
0
|
0
|
TPS
|
wastegate position setpoint(EWGA)(bank1)
|
22 E0 21
|
62 E0
|
B[61]B[60]>32767 ? (B[61]B[60]-65536)*0.00610343454:B[61]B[60]*0.00610343454
|
0
|
0
|
%
|
wastegate position(EWGA)(bank1)
|
22 E0 21
|
62 E0
|
B[59]B[58]>32767 ? (B[59]B[58]-65536)*0.00610343454:B[59]B[58]*0.00610343454
|
0
|
0
|
%
|
air intake temperature at start
|
22 E0 10
|
62 E0
|
B[23]*0.75-48
|
0
|
0
|
°C
|
air mass flow
|
22 E0 10
|
62 E0
|
B[31]B[30]*0.04238956282
|
0
|
0
|
mg/stk
|
reference timer started at IG on
|
22 E0 10
|
62 E0
|
B[11]B[10]*1
|
0
|
0
|
%
|
time since IG key ON
|
22 E0 10
|
62 E0
|
B[29]B[28]*0.01
|
0
|
0
|
s
|
water temperature at start
|
22 E0 10
|
62 E0
|
B[22]*0.75-48
|
0
|
0
|
°C
|
AMS stop reason-blower max switch(AMS)
|
22 E0 09
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
on/off state
|
AMS stop reason-head lamp(AMS)
|
22 E0 09
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
on/off state
|
AMS stop reason-wiper(AMS)
|
22 E0 09
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
on/off state
|
angle to close FPR(fuel pressure regulator)
|
22 E0 23
|
62 E0
|
B[21]B[20]*0.02343755245
|
0
|
0
|
degree CRK
|
angle to open FPR(fuel pressure regulator)
|
22 E0 23
|
62 E0
|
B[19]B[18]*0.023437552452-768
|
0
|
0
|
degree CRK
|
cyl.1 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[38]B[37]*0.004
|
0
|
0
|
ms
|
cyl.1 injection time-2nd pulse
|
22 E0 23
|
62 E0
|
B[30]B[29]*0.004
|
0
|
0
|
ms
|
cyl.2 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[40]B[39]*0.004
|
0
|
0
|
ms
|
cyl.2 injection time-2nd pulse
|
22 E0 23
|
62 E0
|
B[32]B[31]*0.004
|
0
|
0
|
ms
|
cyl.3 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[42]B[41]*0.004
|
0
|
0
|
ms
|
cyl.3 injection time-2nd pulse
|
22 E0 23
|
62 E0
|
B[34]B[33]*0.004
|
0
|
0
|
ms
|
cyl.4 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[44]B[43]*0.004
|
0
|
0
|
ms
|
cyl.4 injection time-2nd pulse
|
22 E0 23
|
62 E0
|
B[36]B[35]*0.004
|
0
|
0
|
ms
|
cyl.5 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[54]B[53]*0.004
|
0
|
0
|
ms
|
cyl.5 injection time-2nd pulse
|
22 E0 23
|
62 E0
|
B[50]B[49]*0.004
|
0
|
0
|
ms
|
cyl.6 injection time-1st pulse
|
22 E0 23
|
62 E0
|
B[56]B[55]*0.004
|
0
|
0
|
ms
|
deviation of fuel pressure setpoint
|
22 E0 23
|
62 E0
|
B[15]B[14]>32767 ? (B[15]B[14]-65536)*5.30669107509:B[15]B[14]*5.30669107509
|
0
|
0
|
hpa
|
fuel pressure
|
22 E0 23
|
62 E0
|
B[9]B[8]*5.306721599145
|
0
|
0
|
hpa
|
fuel pressure set point value
|
22 E0 23
|
62 E0
|
B[11]B[10]*5.30672159914
|
0
|
0
|
hpa
|
injector boot voltage(after DC converter)
|
22 E0 23
|
62 E0
|
B[26]*0.5
|
0
|
0
|
v
|
minimum injection time limitation
|
22 E0 23
|
62 E0
|
B[28]B[27]*0.004
|
0
|
0
|
ms
|
minimum possible fuel injection amount(mg per TDC)
|
22 E0 23
|
62 E0
|
B[48]*0.08478431372
|
0
|
0
|
mg/stk
|
signal voltage of fuel pressure sensor
|
22 E0 23
|
62 E0
|
B[13]B[12]*0.0001528953994048981
|
0
|
0
|
v
|
battery current(AMS)
|
22 E0 0A
|
62 E0
|
B[9]B[8]>32767 ? (B[9]B[8]-65536)*0.1:B[9]B[8]*0.1
|
0
|
0
|
A
|
battery temperature(AMS)
|
22 E0 0A
|
62 E0
|
B[13]B[12]*0.5-40
|
0
|
0
|
°C
|
battery voltage(AMS)
|
22 E0 0A
|
62 E0
|
B[11]B[10]*0.000999923704890+6
|
0
|
0
|
v
|
desired alternator voltage duty cycle(AMS)
|
22 E0 0A
|
62 E0
|
B[18]B[17]*0.001526054
|
0
|
0
|
%
|
duty cycle from alternator PWM signal(AMS)
|
22 E0 0A
|
62 E0
|
B[20]B[19]*0.097700007629
|
0
|
0
|
%
|
nominal capacity(AMS)
|
22 E0 0A
|
62 E0
|
B[21]*1
|
0
|
0
|
Ah
|
state of charge of battery(AMS)
|
22 E0 0A
|
62 E0
|
B[14]*1
|
0
|
0
|
%
|
state of function of battery(AMS)
|
22 E0 0A
|
62 E0
|
B[16]*0.05
|
0
|
0
|
v
|
state of health of battery(AMS)
|
22 E0 0A
|
62 E0
|
B[15]*1
|
0
|
0
|
%
|
boolean for law value of LPG switch allowing fuel feeding
|
22 E0 06
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
on 0/off 1
|
condition for current reduced FPR control
|
22 E0 06
|
62 E0
|
B[10]&(1<<6)
|
0
|
0
|
on/off state
|
fuel pressure control active
|
22 E0 06
|
62 E0
|
B[10]&(1<<7)
|
0
|
0
|
on/off state
|
indicating lamp ON state when fuel pressure built-in
|
22 E0 06
|
62 E0
|
B[9]&(1<<4)
|
0
|
0
|
on/off state
|
limphome opeartion(fuel low pressure control)
|
22 E0 06
|
62 E0
|
B[10]&(1<<5)
|
0
|
0
|
on/off state
|
logical variable for electrical fuel pump active
|
22 E0 06
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
on/off state
|
on/off state of fuel cut-off solenoid valve 1 on regulator side
|
22 E0 06
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
on/off state
|
on/off state of fuel cut-off solenoid valve 2 on regulator side
|
22 E0 06
|
62 E0
|
B[8]&(1<<4)
|
0
|
0
|
on/off state
|
brake boost vacuum pressure voltage(ISG)
|
22 E0 13
|
62 E0
|
B[9]B[8]*0.004882734416
|
0
|
0
|
v
|
brake boost vacuum pressure(ISG)
|
22 E0 13
|
62 E0
|
B[11]B[10]>32767 ? (B[11]B[10]-65536)*0.04:B[11]B[10]*0.04
|
0
|
0
|
hpa
|
starter relay activation counter by ISG(ISG)
|
22 E0 13
|
62 E0
|
B[19]B[18]B[17]B[16]
|
0
|
0
|
|
starter relay activation counter by key(ISG)
|
22 E0 13
|
62 E0
|
B[23]B[22]B[21]B[20]
|
0
|
0
|
|
total starter relay activation counter(key+ISG)(ISG)
|
22 E0 13
|
62 E0
|
B[15]B[14]B[13]B[12]
|
0
|
0
|
|
control camshaft postion setpoint exhaust-bank1(option)
|
22 E0 20
|
62 E0
|
B[24]B[23]>32767 ? (B[24]B[23]-65536)*0.00781243297:B[24]B[23]*0.00781243297
|
0
|
0
|
degree CRK
|
control camshaft postion setpoint exhaust-bank2(option)
|
22 E0 20
|
62 E0
|
B[28]B[27]>32767 ? (B[28]B[27]-65536)*0.007812432978:B[28]B[27]*0.007812432978
|
0
|
0
|
degree CRK
|
control camshaft position setpoint inlet-bank1
|
22 E0 20
|
62 E0
|
B[22]B[21]>32767 ? (B[22]B[21]-65536)*0.00781243297:B[22]B[21]*0.00781243297
|
0
|
0
|
degree CRK
|
control camshaft position setpoint inlet-bank2
|
22 E0 20
|
62 E0
|
B[26]B[25]>32767 ? (B[26]B[25]-65536)*0.00781243297:B[26]B[25]*0.00781243297
|
0
|
0
|
degree CRK
|
current position of exhaust camshaft-bank1(option)
|
22 E0 20
|
62 E0
|
B[16]B[15]>32767 ? (B[16]B[15]-65536)*0.0078124329:B[16]B[15]*0.0078124329
|
0
|
0
|
degree CRK
|
current position of exhaust camshaft-bank2(option)
|
22 E0 20
|
62 E0
|
B[20]B[19]>32767 ? (B[20]B[19]-65536)*0.0078124329:B[20]B[19]*0.0078124329
|
0
|
0
|
degree CRK
|
current position of inlet camshaft-bank1
|
22 E0 20
|
62 E0
|
B[14]B[13]>32767 ? (B[14]B[13]-65536)*0.00781243297:B[14]B[13]*0.00781243297
|
0
|
0
|
degree CRK
|
current position of inlet camshaft-bank2
|
22 E0 20
|
62 E0
|
B[18]B[17]>32767 ? (B[18]B[17]-65536)*0.00781243297:B[18]B[17]*0.00781243297
|
0
|
0
|
degree CRK
|
current value from adaptation table for holding pulse width modulation_inlet
|
22 E0 20
|
62 E0
|
B[34]B[33]>32767 ? (B[34]B[33]-65536)*0.006103434541:B[34]B[33]*0.006103434541
|
0
|
0
|
%
|
current value from adaptation table for holding pulse width modulation;exhaust(option)
|
22 E0 20
|
62 E0
|
B[36]B[35]>32767 ? (B[36]B[35]-65536)*0.00610343454:B[36]B[35]*0.00610343454
|
0
|
0
|
%
|
CVVL state
|
22 E0 20
|
62 E0
|
B[12]
|
0
|
0
|
IVVT state
|
ex-camshaft position deviation integrator for diagnosis
|
22 E0 20
|
62 E0
|
B[38]B[37]*0.004095979247
|
0
|
0
|
degree CRK
|
ex-camshaft position deviation integrator for reference check
|
22 E0 20
|
62 E0
|
B[42]B[41]*0.004095979247
|
0
|
0
|
degree CRK
|
holding pulse width-inlet CVVT
|
22 E0 20
|
62 E0
|
B[30]B[29]*0.006103456168
|
0
|
0
|
%
|
in-camshaft position deviation integrator for diagnosis
|
22 E0 20
|
62 E0
|
B[40]B[39]*0.00409597924
|
0
|
0
|
degree CRK
|
in-camshaft position deviation integrator for reference check
|
22 E0 20
|
62 E0
|
B[44]B[43]*0.00409597924
|
0
|
0
|
degree CRK
|
OCV holding pulse width-exhaust CVVT(option)
|
22 E0 20
|
62 E0
|
B[32]B[31]*0.006103456168
|
0
|
0
|
%
|
distance after MIL on
|
22 E0 1B
|
62 E0
|
B[9]B[8]*1
|
0
|
0
|
km
|
distance since DTC cleared
|
22 E0 1B
|
62 E0
|
B[11]B[10]*1
|
0
|
0
|
km
|
door switch(ISG)
|
22 E0 12
|
62 E0
|
B[10]&(1<<6)
|
0
|
0
|
بسته شده/بسته نشده
|
driver s seat blet(ISG)
|
22 E0 12
|
62 E0
|
B[10]&(1<<5)
|
0
|
0
|
وضعيت سوييچ جاخور کمربند راننده
|
hood switch(ISG)
|
22 E0 12
|
62 E0
|
B[10]&(1<<7)
|
0
|
0
|
بسته شده/بسته نشده
|
ISG inhibition by battery management system errors(ISG)
|
22 E0 12
|
62 E0
|
B[18]&(1<<4)
|
0
|
0
|
on/off state
|
ISG inhibition by CAN general error(ISG)
|
22 E0 12
|
62 E0
|
B[19]&(1<<7)
|
0
|
0
|
on/off state
|
ISG inhibition by cluster CAN message error(ISG)
|
22 E0 12
|
62 E0
|
B[19]&(1<<5)
|
0
|
0
|
on/off state
|
ISG inhibition by door open(ISG)
|
22 E0 12
|
62 E0
|
B[22]&(1<<6)
|
0
|
0
|
on/off state
|
ISG inhibition by EMS related errors(ISG)
|
22 E0 12
|
62 E0
|
B[18]&(1<<6)
|
0
|
0
|
on/off state
|
ISG inhibition by engine hood open(ISG)
|
22 E0 12
|
62 E0
|
B[22]&(1<<7)
|
0
|
0
|
on/off state
|
ISG inhibition by engine stall without ISG stop request(ISG)
|
22 E0 12
|
62 E0
|
B[22]&(1<<4)
|
0
|
0
|
on/off state
|
ISG inhibition by ISG related components errors(ISG)
|
22 E0 12
|
62 E0
|
B[18]&(1<<5)
|
0
|
0
|
on/off state
|
ISG inhibition by safety belt open(ISG)
|
22 E0 12
|
62 E0
|
B[22]&(1<<5)
|
0
|
0
|
on/off state
|
ISG inhibition by safety related errors(ISG)
|
22 E0 12
|
62 E0
|
B[18]&(1<<7)
|
0
|
0
|
on/off state
|
ISG inhibition by SAS CAN message error(ISG)
|
22 E0 12
|
62 E0
|
B[19]&(1<<4)
|
0
|
0
|
on/off state
|
ISG inhibition by starter relay maximum allows limit reached(ISG)
|
22 E0 12
|
62 E0
|
B[20]&(1<<6)
|
0
|
0
|
on/off state
|
ISG inhibition by TCU CAN message error(ISG)
|
22 E0 12
|
62 E0
|
B[19]&(1<<6)
|
0
|
0
|
on/off state
|
ISG inhibition by too long idle stop duration(ISG)
|
22 E0 12
|
62 E0
|
B[23]&(1<<7)
|
0
|
0
|
on/off state
|
ISG inhibition by unintended start detected by ECM(ISG)
|
22 E0 12
|
62 E0
|
B[20]&(1<<7)
|
0
|
0
|
on/off state
|
ISG inhibition lamp(ISG)
|
22 E0 12
|
62 E0
|
B[8]&(1<<4)
|
0
|
0
|
on/off state
|
ISG inhibition switch(ISG)
|
22 E0 12
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
on/off state
|
ISG status(ISG)
|
22 E0 12
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
on 0/off 1
|
ISG system built-in(ISG)
|
22 E0 12
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
on/off state
|
no idle stop by aircondition on and blower max(ISG)
|
22 E0 12
|
62 E0
|
B[14]&(1<<6)
|
0
|
0
|
on/off state
|
no idle stop by ambient pressure low(ISG)
|
22 E0 12
|
62 E0
|
B[11]&(1<<5)
|
0
|
0
|
on/off state
|
no idle stop by ambient temperature too low(ISG)
|
22 E0 12
|
62 E0
|
B[16]&(1<<4)
|
0
|
0
|
on/off state
|
no idle stop by battery condition(SOC)(ISG)
|
22 E0 12
|
62 E0
|
B[14]&(1<<5)
|
0
|
0
|
on/off state
|
no idle stop by battery condition(SOH)(ISG)
|
22 E0 12
|
62 E0
|
B[14]&(1<<4)
|
0
|
0
|
on/off state
|
no idle stop by battery condition(current)(ISG)
|
22 E0 12
|
62 E0
|
B[15]&(1<<5)
|
0
|
0
|
on/off state
|
no idle stop by battery condition(SOF)(ISG)
|
22 E0 12
|
62 E0
|
B[15]&(1<<7)
|
0
|
0
|
on/off state
|
no idle stop by battery condition(voltage)(ISG)
|
22 E0 12
|
62 E0
|
B[15]&(1<<6)
|
0
|
0
|
on/off state
|
no idle stop by brake pressure too low(ISG)
|
22 E0 12
|
62 E0
|
B[14]&(1<<7)
|
0
|
0
|
on/off state
|
no idle stop by catalyst heating active(ISG)
|
22 E0 12
|
62 E0
|
B[12]&(1<<6)
|
0
|
0
|
on/off state
|
no idle stop by catalyst temperature low(ISG)
|
22 E0 12
|
62 E0
|
B[11]&(1<<6)
|
0
|
0
|
on/off state
|
no idle stop by engine temperature(ISG)
|
22 E0 12
|
62 E0
|
B[11]&(1<<7)
|
0
|
0
|
on/off state
|
no idle stop by FATC request(ISG)
|
22 E0 12
|
62 E0
|
B[16]&(1<<6)
|
0
|
0
|
on/off state
|
no idle stop by lambda adaptation active(ISG)
|
22 E0 12
|
62 E0
|
B[11]&(1<<4)
|
0
|
0
|
on/off state
|
no idle stop by road slope too high(ISG)
|
22 E0 12
|
62 E0
|
B[16]&(1<<7)
|
0
|
0
|
on/off state
|
no idle stop by steering angle too high(ISG)
|
22 E0 12
|
62 E0
|
B[15]&(1<<4)
|
0
|
0
|
on/off state
|
no idle stop by TCU request(ISG)
|
22 E0 12
|
62 E0
|
B[16]&(1<<5)
|
0
|
0
|
on/off state
|
no idle stop by torque system(ISG)
|
22 E0 12
|
62 E0
|
B[12]&(1<<7)
|
0
|
0
|
on/off state
|
start request from ISG(ISG)
|
22 E0 12
|
62 E0
|
B[9]&(1<<7)
|
0
|
0
|
|
start request from key
|
22 E0 12
|
62 E0
|
B[9]&(1<<5)
|
0
|
0
|
|
starter relay on signal
|
22 E0 12
|
62 E0
|
B[9]&(1<<4)
|
0
|
0
|
on/off state
|
stop request from ISG(ISG)
|
22 E0 12
|
62 E0
|
B[9]&(1<<6)
|
0
|
0
|
on/off state
|
frequency of EFP diagnostic signal
|
22 E0 22
|
62 E0
|
B[16]*0.1
|
0
|
0
|
HZ
|
global status of electrical fuel pump function
|
22 E0 22
|
62 E0
|
B[14]
|
0
|
0
|
global status of electrical fuel pump function
|
LPG pressure in the fuel rail mean value
|
22 E0 22
|
62 E0
|
B[11]B[10]*0.5
|
0
|
0
|
hpa
|
LPG pressure in the fuel rail voltage law value
|
22 E0 22
|
62 E0
|
B[13]B[12]*0.004882887006
|
0
|
0
|
v
|
measured LPG temperature low side
|
22 E0 22
|
62 E0
|
B[8]*0.75-48
|
0
|
0
|
°C
|
natural gas temperature low side or LPG fuel rail temperature
|
22 E0 22
|
62 E0
|
B[9]*0.01952941176
|
0
|
0
|
v
|
percentage of butance in the LPG
|
22 E0 22
|
62 E0
|
B[17]*0.389098039215
|
0
|
0
|
%
|
pump speed of the LPG electrical fuel pump as PWM signal
|
22 E0 22
|
62 E0
|
B[15]*0.39062745098
|
0
|
0
|
%
|
fuel adaption(idle)-bank1
|
22 E0 19
|
62 E0
|
B[10]B[9]>32767 ? (B[10]B[9]-65536)*0.04687490425:B[10]B[9]*0.04687490425
|
0
|
0
|
%
|
fuel adaption(idle)-bank2
|
22 E0 19
|
62 E0
|
B[14]B[13]>32767 ? (B[14]B[13]-65536)*0.0468749042:B[14]B[13]*0.0468749042
|
0
|
0
|
%
|
fuel adaption(part load)-bank1
|
22 E0 19
|
62 E0
|
B[12]B[11]>32767 ? (B[12]B[11]-65536)*0.0468749042:B[12]B[11]*0.0468749042
|
0
|
0
|
%
|
fuel adaption(part load)-bank2
|
22 E0 19
|
62 E0
|
B[16]B[15]>32767 ? (B[16]B[15]-65536)*0.0468749042:B[16]B[15]*0.0468749042
|
0
|
0
|
%
|
knock control adaptation value cylinder#1
|
22 E0 19
|
62 E0
|
B[25]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#2
|
22 E0 19
|
62 E0
|
B[26]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#3
|
22 E0 19
|
62 E0
|
B[27]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#4
|
22 E0 19
|
62 E0
|
B[28]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#5
|
22 E0 19
|
62 E0
|
B[29]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#6
|
22 E0 19
|
62 E0
|
B[30]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#7
|
22 E0 19
|
62 E0
|
B[31]*0.75-191.25
|
0
|
0
|
degree CRK
|
knock control adaptation value cylinder#8
|
22 E0 19
|
62 E0
|
B[32]*0.75-191.25
|
0
|
0
|
degree CRK
|
immobilizer built-in
|
22 E0 03
|
62 E0
|
B[8]&(1<<5)
|
0
|
0
|
ok status
|
MAF sensor built-in
|
22 E0 03
|
62 E0
|
B[8]&(1<<6)
|
0
|
0
|
ok status
|
MAP sensor built-in
|
22 E0 03
|
62 E0
|
B[8]&(1<<7)
|
0
|
0
|
ok status
|
injection time-inj.1
|
22 E0 02
|
62 E0
|
B[27]B[26]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.2
|
22 E0 02
|
62 E0
|
B[29]B[28]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.3
|
22 E0 02
|
62 E0
|
B[31]B[30]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.4
|
22 E0 02
|
62 E0
|
B[33]B[32]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.5
|
22 E0 02
|
62 E0
|
B[35]B[34]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.6
|
22 E0 02
|
62 E0
|
B[37]B[36]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.7
|
22 E0 02
|
62 E0
|
B[39]B[38]*0.819199969481
|
0
|
0
|
ms
|
injection time-inj.8
|
22 E0 02
|
62 E0
|
B[41]B[40]*0.819199969481
|
0
|
0
|
ms
|
O2 sensor binary type bank 1 downstream(option)
|
22 E0 02
|
62 E0
|
B[10]*0.00521568627-0.2
|
0
|
0
|
v
|
O2 sensor binary type bank 1 upstream(option)
|
22 E0 02
|
62 E0
|
B[8]*0.00521568627-0.2
|
0
|
0
|
v
|
O2 sensor binary type bank2 downstream
|
22 E0 02
|
62 E0
|
B[11]*0.00521568627-0.2
|
0
|
0
|
v
|
O2 sensor binary type bank 2 upstream(option)
|
22 E0 02
|
62 E0
|
B[9]*0.00521568627-0.2
|
0
|
0
|
v
|
O2 sensor linear type bank 1 upstream(option)
|
22 E0 02
|
62 E0
|
B[13]B[12]*0.004800030518
|
0
|
0
|
v
|
O2 sensor linear type bank 2 upstream(option)
|
22 E0 02
|
62 E0
|
B[15]B[14]*0.004800030518
|
0
|
0
|
v
|
purge control valve
|
22 E0 02
|
62 E0
|
B[24]B[23]*0.001526054779
|
0
|
0
|
%
|
relative charge value
|
22 E0 02
|
62 E0
|
B[18]B[17]*0.02343755245
|
0
|
0
|
%
|
سرعت وسيله نقليه
|
22 E0 02
|
62 E0
|
B[16]*1.25
|
0
|
0
|
km/h
|
OIL level filtered value
|
22 E0 27
|
62 E0
|
B[9]*0.5
|
0
|
0
|
mm
|
OIL level last averaged value
|
22 E0 27
|
62 E0
|
B[11]*0.5
|
0
|
0
|
mm
|
OIL level raw value
|
22 E0 27
|
62 E0
|
B[8]*0.5
|
0
|
0
|
mm
|
OIL status
|
22 E0 27
|
62 E0
|
B[12]%8
|
0
|
0
|
OIL status
|
OIL temperature
|
22 E0 27
|
62 E0
|
B[10]*1-40
|
0
|
0
|
°C
|
total counter of catalyst damaing misfiring of cylinder#1
|
22 E0 1D
|
62 E0
|
B[25]B[24]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#2
|
22 E0 1D
|
62 E0
|
B[27]B[26]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#3
|
22 E0 1D
|
62 E0
|
B[29]B[28]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#4
|
22 E0 1D
|
62 E0
|
B[31]B[30]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#5
|
22 E0 1D
|
62 E0
|
B[33]B[32]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#6
|
22 E0 1D
|
62 E0
|
B[35]B[34]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#7
|
22 E0 1D
|
62 E0
|
B[37]B[36]*1
|
0
|
0
|
|
total counter of catalyst damaing misfiring of cylinder#8
|
22 E0 1D
|
62 E0
|
B[39]B[38]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#1
|
22 E0 1D
|
62 E0
|
B[9]B[8]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#2
|
22 E0 1D
|
62 E0
|
B[11]B[10]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#3
|
22 E0 1D
|
62 E0
|
B[13]B[12]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#4
|
22 E0 1D
|
62 E0
|
B[15]B[14]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#5
|
22 E0 1D
|
62 E0
|
B[17]B[16]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#6
|
22 E0 1D
|
62 E0
|
B[19]B[18]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#7
|
22 E0 1D
|
62 E0
|
B[21]B[20]*1
|
0
|
0
|
|
total counter of emission relevant misfiring of cylinder#8
|
22 E0 1D
|
62 E0
|
B[23]B[22]*1
|
0
|
0
|
|